The iGS-220 CO2 relative humidity and temperature controller is the simplest and most complete solution to integrated climate management and CO2 enrichment or venting. The resulting climate can increase yields and quality of harvest while insuring CO2 and energy savings. The electronic module displays the actual values of the CO2, relative humidity and temperature sensors. The controller includes an internal fan to speed up the air sampling process thus yielding better climate control. The control unit can
iGS Day & Night Humidity Control With Display The iGS-030 relative humidity controller will operate your humidifying or dehumidifying equipment in accordance to user day and night set points. The ambient relative humidity is displayed on the luminous bar graph. The precision RH sensor (3%) can be calibrated and the differential of operation is adjustable. This controller is also available with a remote (10 feet) sensor (iGS-030R). Details IGS030 Day & Night Humidity Control With Display IGS030R Day & Night
iGS-110 Day & Night Temperature & Relative Humidity Control Dimensions: 9x6.75x3.5 Weight: 4.22 (lbs) Product Number: 703560 Maximum load both outputs: 15 Amp 120 volt AC RH Sensor and control range: 0%-100% Auto differential adjustment: 3 to 10% Annual drift: 1% Accuracy of RH sensor: 3% Calibration of RH sensor: factory calibrated Temperature sensor and control range: -20C to +50C (-4F to +122F) Auto. Differential adjustment: 1C to 10C (-1,8F to +18F) Accuracy of temperature sensor: 1C (2F) Resolution of
8/70# Ammonia P74 Series Differential Pressure Control ClosHi, 15# DifSet PRS74BA15 $326.86 Description: 8 /70 #AmmonDif #ClosHi ,15 #DifSet Category: Refrigeration Controls P74 Series Differential Pressure Controls These differential pressure controls are for use as operating controls and/or indicating system functions through display lights or panels. They measure the difference in pressure exerted upon its two sensing elements. The controls are available for applications sensing air, oil or liquid.
Snap Disc Limit Control Features SPST Flanged Airstream Mount Open On Rise Adjustable Set Point 135 to 175 Degrees F Range Automatic Reset
[Item # TMP-DNE] Heating/Cooling Thermostat (TMP-DNE) DAY/NIGHT TEMPERATURE CONTROL The TMP-DNe allows you to control the temperature within your growing environment. You can set the day and night temperature independently. The TMP-DNe can be set to either heat or cool. Just connect your equipment, then set the temperature that you wish to maintain. If the temperature varies from your setting, the outlet on the front is activated. The temperature differential can be set at 3, 5 or 7 degrees. Comes with a
A basic temperature differential controller for solar water heating systems, this microprocessor based temperature controller regulates solar water heating systems and any other heating systems such as: storage tank charging and boiler activation systems. The USDT 2004B monitors and displays supply and return temperatures. When the supply temperature exceeds the return temperature by a programmable temperature difference (?T), an internal relay powers a 0.25 HP pump or an auxiliary relay. To avoid
8/70# Ammonia Differential Pressure Control, ClosHi, 10# DifSet PRS74BA9 $331.84 Description: 8 /70 #AmmonDif #ClosHi ,10 #DifSet Sub Category: Pressure Controls P74 Series Differential Pressure Controls The controls are available for applications sensing air, oil or liquid. Typical applications are proof of flow across a chiller or water cooled condenser, proof of flow in a heating or cooling coil and lube oil pressure sensing on refrigeration compressors. On a proof of flow application the control
Ideal for Replacement of Similar Type Controls Features For use where space is limited Small bimetal sensing element Snap-Action switch Fan control has adjustable range with direct reading temperature dial has adjustable limit setting
dwyer-DHII-004 596.95 dwyer-DHII-006 dwyer-DHII-007 Dwyer-MS-121 78.20 Dwyer-MS-122 96.03 Dwyer-MS-321 78.20 DA-41-2-11E 418.02 DA-41-2-13E 405.55 DA-31-3-2 DA-31-3-3 DA-31-3-27 DA-31-3-1 DA-31-3-3A DA-31-3-4 DA-31-3-5 Page 60 of 78 dwyer-DHII-004 Digihelic? II Differential Pressure Controller NEMA 4 (IP66) Housing with Large, Bright LCD Pressure Units - in. wc = 1.000 Pressure Units - mm wc = 25.40 Pressure Units - cm wc = 2.540 Pressure Units - mm Hg = 1.868 Pressure Units - mbar = 2.491 Pressure Units -
2-26# 1.5 Fixed Diff. Capillary - P74 Series Differential Pressure Control PRS74F10 $245.23 The controls are available for applications sensing air, oil or liquid. Typical applications are proof of flow across a chiller or water cooled condenser, proof of flow in a heating or cooling coil and lube oil pressure sensing on refrigeration compressors. On a proof of flow application the control measures pressure drop across two different points in either a closed water circulating system or a city water to
Ideal for Replacement of Similar Type Controls Features For use where space is limited Small bimetal sensing element Snap-Action switch Fan control has adjustable range with direct reading temperature dial
2-26# 1.5 Fixed Diff. Capillary - P74 Series Differential Pressure Control PRS74F10 $245.23 The controls are available for applications sensing air, oil or liquid. Typical applications are proof of flow across a chiller or water cooled condenser, proof of flow in a heating or cooling coil and lube oil pressure sensing on refrigeration compressors. On a proof of flow application the control measures pressure drop across two different points in either a closed water circulating system or a city water to
Flush Mount Limit Control, 110 To 200 Deg. F Range, 25 Deg. F Fixed Differential, Open On Rise Flush Mount Limit Control, 110 To 200 Deg. F Range, 25 Deg. F Fixed Differential, Open On Rise Description Ideal for Replacement of Similar Type Controls Features For use where space is limited Small bimetal sensing element Snap-Action switch Fan control has adjustable range with direct reading temperature dial has adjustable limit setting Due to the great level of control with a programmable thermostat, these
2-26# 1.5 Fixed Diff. Capillary - P74 Series Differential Pressure Control PRS74F10 $245.23 The controls are available for applications sensing air, oil or liquid. Typical applications are proof of flow across a chiller or water cooled condenser, proof of flow in a heating or cooling coil and lube oil pressure sensing on refrigeration compressors. On a proof of flow application the control measures pressure drop across two different points in either a closed water circulating system or a city water to
Snap-Acting SPDT Factory Replacement Differential Pressure Control (Johnson Controls) PRSD74EA8CP $244.95 Snap-Acting SPDT Factory Replacement Differential Pressure Control (Johnson Controls) Features Description • field-proven Pennswitch with a completely enclosed contact mechanism • pressure differential setting is easily changed without removing the cover Accessories • Includes a universal mounting bracket Applications • differential pressure sensing on chillers or water-cooled condensers • lube oil
Tech Specs: 1630 DIFFERENTIAL PRESSURE SWITCH OPERATING RANGE .05 TO .25
Fast Response Hydronic Control, 100-240 Degrees F Range, 5-45 Degrees F Adjustable Differential Fast Response Hydronic Control, 100-240 Degrees F Range, 5-45 Degrees F Adjustable Differential Description 1145-33 Control has Thermal Element Immersed Directly in the Water for use as a High Limit and/or Operating Control. Use as a High Limit, Low Limit Circulator Control or Combination Low Limit and Circulator Control. Specifications Specially designed hydraulic action element for fast response to temperature